POWER WINDOW CONTROL SYSTEM Rear Power Window RH Auto Up / Down Function does not Operate with Rear Power Window Switch RH

DESCRIPTION



WIRING DIAGRAM

A01ENEQE08

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK FOR DTC


    1. Check for DTCs Click here.

      Result:
      Result Proceed to
      DTC is not output A
      B2311 is output B
      B2312 is output C
      B2313 is output D
      LIN communication system DTCs are output E

    B
    C
    D
    E
    A
  2. CHECK MANUAL UP/DOWN FUNCTION (REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH)


    1. Check that the manual up/down function using the rear power window regulator switch RH can operate the rear door power window RH Click here.

      OK
      Manual up/down function operates.

    NG
    OK
  3. READ VALUE USING INTELLIGENT TESTER (REAR POWER WINDOW REGULATOR MOTOR RH)


    1. Use the Data List to check if the power window regulator motor is functioning properly Click here.

      RR-Door Motor
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      RR Door P/W Auto SW Rear power window RH auto up/down signal / ON or OFF

      ON: Rear power window RH auto up/down switch operated

      OFF: Rear power window RH switch not operated

      -
      OK
      Display changes according to operation of rear power window switch RH.

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (REAR POWER WINDOW REGULATOR SWITCH RH - REAR POWER WINDOW REGULATOR MOTOR RH)


    1. A01ERZLE14

      Disconnect the J3 switch connector.

    2. Disconnect the J4 motor connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J3-4 (AUTO) - J4-4 (AUTO) Always Below 1 Ω
      J3-4 (AUTO) or J4-4 (AUTO) - Body ground Always 10 kΩ or higher

    NG
    OK
  5. INSPECT REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY RH

    A01EQ4OE07

    1. Remove the rear power window regulator switch Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (AUTO) - 5 (GND) Auto up/down operation Below 1 Ω

    NG
    OK