CANISTER INSPECTION


  1. INSPECT CANISTER


    1. A01EQO6E01

      Visually check the canister for cracks or damage.

    2. Blow compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A and check that air flows without resistance from port B and port C.

      If the result is not as specified, replace the canister.

    3. Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum does not decrease when port B is released.

      If the result is not as specified, replace the canister.

  2. CLEAN FILTER IN CANISTER


    1. A01ERD5E01

      Clean the filter by blowing compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A while holding port B closed.

      Note

      Do not attempt to wash the canister.