INSPECT AIR SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
*: Make sure that the air switching valve is at ambient temperature before measuring the resistance.
Note
When measuring the resistance, do not touch terminals 2, 3 and 4.
If the result is not as specified, replace the air switching valve assembly.
Check the operation of the air switching valve.
Check that air does not flow from port A to port B.
Note
Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less
If the result is not as specified, replace the air switching valve assembly.
Apply battery voltage to the connector, and check the air switching valve operation.
| OK | ||||
|---|---|---|---|---|
|
Note
When applying voltage, do not touch terminals 2, 3 and 4.
If the result is not as specified, replace the air switching valve assembly.