INSPECT AIR PUMP ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the air pump assembly.
Check the operation of the air pump.
Check that air does not flow from port A to port B.
Apply battery voltage to the connector, and check the air pump operation.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the air pump assembly.
Note
Do not operate the air pump continuously for 2 minutes or more.
When operating the air pump, wait 5 minutes until the pump has cooled down between each operation. If the pump has not cooled down sufficiently, the motor will burn out.