INSPECT MASS AIR FLOW METER
Check the output voltage.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).
Note
While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG), and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the MAF meter and check that the voltage fluctuates.
If the result is not as specified, replace the MAF meter.
Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.
| OK |
|---|
| There is no foreign matter. |
If the result is not as specified, replace the mass air flow meter.
Check the IAT sensor.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the MAF meter.