SFI SYSTEM, Diagnostic DTC:P0112, P0113

DTC Code DTC Name
P0112 Intake Air Temperature Circuit Low Input
P0113 Intake Air Temperature Circuit High Input

DESCRIPTION

A01EO3XE12

DTC Code DTC Detection Condition Trouble Area
P0112 A short in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
  • Short in IAT sensor circuit

  • IAT sensor (built into MAF meter)

  • ECM

P0113 An open in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
  • Open in IAT sensor circuit

  • IAT sensor (built into MAF meter)

  • ECM

Tech Tips

When any of these DTCs are output, check the IAT by entering the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit

MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the IAT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the IAT sensor and stores a DTC.

Example:

If the sensor output voltage is higher than 4.91 V for 0.5 seconds or more, the ECM determines that there is an open in the IAT sensor circuit, and stores DTC P0113. Conversely, if the output voltage is below 0.18 V for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and stores DTC P0112.

If the malfunction is not repaired successfully, a DTC is stored 0.5 seconds after the engine is next started.

WIRING DIAGRAM

A01EQINE60

INSPECTION PROCEDURE

Tech Tips

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

    5. Read the value displayed on the tester.

      Standard
      Same as actual Intake Air Temperature (IAT).
      Result
      Temperature Displayed Proceed to
      -40°C (-40°F) A
      140°C (284°F) or higher B
      Same as actual IAT C

      Tech Tips


      • If there is an open circuit, the tester indicates -40°C (-40°F).


      • If there is a short circuit, the tester indicates 140°C (284°F) or higher.


    B
    C
    A
  2. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS)

    A01EO1VE76

    1. Disconnect the Mass Air Flow (MAF) meter connector.

    2. Connect terminals 4 (THA) and 5 (E2) of the MAF meter wire harness side connector.

    3. Connect the intelligent tester to the DLC3.

    4. Turn the engine switch on (IG).

    5. Turn the tester on.

    6. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

    7. Read the value displayed on the tester.

      Standard value
      140°C (284°F) or higher

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)

    A01ES8YE11

    1. Disconnect the MAF meter connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      C3-4 (THA) - C53-73 (THA) Always Below 1 Ω
      C3-5 (E2) - C53-98 (ETHA) Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      C3-4 (THA) - C54-73 (THA) Always Below 1 Ω
      C3-5 (E2) - C54-98 (ETHA) Always Below 1 Ω

    NG
    OK
  4. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)

    A01EQJOE28

    1. Disconnect the MAF meter connector.

    2. Connect the intelligent tester to the DLC3.

    3. Turn the engine switch on (IG).

    4. Turn the tester on.

    5. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

    6. Read the value displayed on the tester.

      Standard value
      -40°C (-40°F)

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)

    A01ES8YE06

    1. Disconnect the MAF meter connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      C3-4 (THA) or C53-73 (THA) - Body ground Always 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      C3-4 (THA) or C54-73 (THA) - Body ground Always 10 kΩ or higher

    NG
    OK