ACCESS MODE SWITCH INSPECTION


  1. INSPECT COMBINATION SWITCH ASSEMBLY (EASY ACCESS MODE SWITCH)


    1. A01ESB1E03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      6 (ECU1) - 3 (GND) Pushed and held Below 1 Ω
      Not pushed 10 kΩ or higher

      If the result is not as specified, replace the combination switch assembly.