HEIGHT CONTROL SENSOR (for Front Side) INSPECTION


  1. INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY LH

    A01ERVZE03

    Note

    Do not drop the height control sensor. If it is dropped, replace it with a new one.


    1. Connect 3 dry batteries of 1.5 V in series.

    2. Connect the positive (+) end of the batteries to terminal 3 (SHB) of the height control sensor and the negative (-) end of the batteries to terminal 1 (SHG). While slowly moving the sensor link up and down, measure the voltage between terminal 2 (SHFR*1, SHFL*2) and terminal 1 (SHG).

      Tech Tips

      *1: for RH

      *2: for LH


      1. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        for RH
        Tester Connection Condition Specified Condition
        2 (SHFR) - 1 (SHG) Max. HI Approx. 4.1 V
        Normal Approx. 2.25 V
        Min. LO Approx. 0.45 V
        for LH
        Tester Connection Condition Specified Condition
        2 (SHFL) - 1 (SHG) Max. HI Approx. 4.1 V
        Normal Approx. 2.25 V
        Min. LO Approx. 0.45 V

        Note

        Do not apply a voltage of higher than 6 V.

        If the result is not as specified, replace the front height control sensor.