DAMPING FORCE CONTROL ACTUATOR (for Rear Side) INSPECTION


  1. INSPECT REAR SHOCK ABSORBER CONTROL VALVE ASSEMBLY

    A01ES0IE05

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RH
      Tester Connection Condition Specified Condition
      1 (RAR+) - 2 (E RR) Always 12.0 to 13.6 Ω
      3 (RBR-) - 2 (E RR)
      4 (RAR-) - 2 (E RR)
      5 (RBR+) - 2 (E RR)
      for LH
      Tester Connection Condition Specified Condition
      1 (RAL+) - 2 (E RL) Always 12.0 to 13.6 Ω
      3 (RBL-) - 2 (E RL)
      4 (RAL-) - 2 (E RL)
      5 (RBL+) - 2 (E RL)

      • If the result is not as specified, replace the shock absorber control valve.