DAMPING FORCE CONTROL ACTUATOR (for Front Side) INSPECTION


  1. INSPECT FRONT SHOCK ABSORBER CONTROL VALVE ASSEMBLY


    1. A01ES0IE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RH
      Tester Connection Condition Specified Condition
      1 (FAR+) - 2 (E FR) Always 12.0 to 13.6 Ω
      3 (FBR-) - 2 (E FR)
      4 (FAR-) - 2 (E FR)
      5 (FBR+) - 2 (E FR)
      for LH
      Tester Connection Condition Specified Condition
      1 (FAL+) - 2 (E FL) Always 12.0 to 13.6 Ω
      3 (FBL-) - 2 (E FL)
      4 (FAL-) - 2 (E FL)
      5 (FBL+) - 2 (E FL)

      • If the result is not as specified, replace the shock absorber control valve.

  2. INSPECT FRONT SUSPENSION CONTROL VALVE ASSEMBLY


    1. A01EP1XE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RH
      Tester Connection Condition Specified Condition
      1 (CRFR) - 2 (SLB) 20°C (68°F) 4.58 to 5.02 Ω
      for LH
      Tester Connection Condition Specified Condition
      1 (CRFL) - 2 (SLB) 20°C (68°F) 4.58 to 5.02 Ω

      • If the result is not as specified, replace the shock absorber control valve.