SPEED SENSOR INSPECTION


  1. INSPECT SPEED SENSOR NT

    A01EOESE53

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the sensor.

  2. INSPECT SPEED SENSOR SP2

    A01EOESE54

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the sensor.