AUTOMATIC TRANSMISSION SYSTEM (for 1UR-FE), Diagnostic DTC:P2759

DTC Code DTC Name
P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

DESCRIPTION

The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.

A01EQIEE01
DTC Code DTC Detection Condition Trouble Area
P2759 An open or short is detected in the shift solenoid valve SLU circuit for 1 sec. or more while driving (1 trip detection logic).
  • Open or short in shift solenoid valve SLU circuit

  • Shift solenoid valve SLU

  • ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.

WIRING DIAGRAM

A01EO5RE21

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)


    1. A01EPLNE40
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Transmission Wire)

      Disconnect the No. 1 transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      12 (SLU+) - 4 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      12 (SLU+) - Body ground Always 10 kΩ or higher
      4 (SLU-) - Body ground Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

    A01ERYUE72
    Text in Illustration
    *a

    Front view of wire harness connector

    (to ECM)


    1. Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C54-10 (SLU+) - C54-11 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      C54-10 (SLU+) - Body ground Always 10 kΩ or higher
      C54-11 (SLU-) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLU


    1. A01EQ51E04
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLU)

      Remove shift solenoid valve SLU.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

    NG
    OK