| DTC Code | DTC Name |
|---|---|
| Pre-heating Control Circuit |
DESCRIPTION
When the ignition switch is turned to ON, the ECM calculates the glow indicator lighting time/heating corresponding to the coolant temperature at that time and turns on the glow indicator light/glow plug relay (GLOW).
As ceramic is used for glow plug assembly material, current control is not performed.
INSPECTION PROCEDURE
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK GLOW INDICATOR LIGHT
Turn the ignition switch to ON.
Check that the glow indicator light comes on.
| OK |
|---|
| The glow indicator light remains on for 0.5 seconds or more, and then goes off. |
CHECK GLOW PLUG ASSEMBLY (INSTALLATION)
Check that the glow plug assembly and glow plug wire are securely installed.
| OK |
|---|
| The glow plug assembly and glow plug wire are securely installed. |
INSPECT GLOW PLUG ASSEMBLY (RESISTANCE)
Inspect the glow plug assembly (Click here).
CHECK INDICATOR LIGHTING TIME AND AFTER GLOW TIME
READ OUTPUT DTC
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs (Click here).
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
INSPECT GLOW RELAY ASSEMBLY
Inspect the glow plug relay (GLOW) (Click here).
CHECK ECM (SREL VOLTAGE)
Turn the ignition switch to the start position.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component with harness connected (ECM) |
CHECK HARNESS AND CONNECTOR (GLOW RELAY - ECM AND BODY GROUND)
Disconnect the ECM connector.
Remove the glow relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the ECM connector.
Reinstall the glow relay.
CHECK HARNESS AND CONNECTOR (GLOW PLUG RELAY (GLOW) - GLOW PLUG ASSEMBLY AND BATTERY)
Disconnect the cable from the negative (-) battery terminal.
Disconnect the cable from the positive (+) battery terminal.
Remove the glow relay from the engine room relay block.
Disconnect the glow plug wire.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
After reconnecting the battery cable, the radio and clock need to be adjusted as they were previously.
Reinstall the glow relay.
Reconnect the glow plug wire.
Reconnect the cable to the positive (+) battery terminal.
Reconnect the cable to the negative (-) battery terminal.
CHECK ECM (GIND VOLTAGE)
Disconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *a | Rear view of wire harness connector (to ECM) |
Reconnect the ECM connector.
CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER ASSEMBLY)
Disconnect the combination meter assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the combination meter assembly connector.
Reconnect the ECM connector.
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)
Disconnect the combination meter assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Reconnect the combination meter assembly connector.
TIGHTEN GLOW PLUG ASSEMBLY
REPLACE GLOW PLUG ASSEMBLYClick here
REPLACE ECMClick here
GO TO RELEVANT DTC CHARTClick here
REPLACE GLOW PLUG RELAY (GLOW)
REPLACE ECMClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE COMBINATION METER ASSEMBLYClick here
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here