Click here

POWER SLIDE DOOR TOUCH SENSOR INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT POWER SLIDE DOOR TOUCH SENSOR ASSEMBLY LH


    1. A01CEABE06

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L6-1 (OS) - L6-2 (OSG) Pressed Below 100 Ω
      L6-1 (OS) - L6-2 (OSG) Free 0.95 to 1.05 kΩ

      • If the result is not as specified, replace the power slide door touch sensor LH.

  2. Click here

    INSPECT POWER SLIDE DOOR TOUCH SENSOR ASSEMBLY RH


    1. A01CEABE07

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K6-1 (OS) - K6-2 (OSG) Pressed Below 100 Ω
      K6-1 (OS) - K6-2 (OSG) Free 0.95 to 1.05 kΩ

      • If the result is not as specified, replace the power slide door touch sensor RH.