INSPECT SLIDE DOOR LOCK RELEASE MOTOR ASSEMBLY LH
Apply battery voltage to the motor terminals and check the operation of the slide door lock release motor assembly LH.
| OK | ||||||
|---|---|---|---|---|---|---|
|
| Standard Stroke |
|---|
| 26.0 to 30.3 mm (1.02 to 1.19 in.) |
If the result is not as specified, replace the slide door lock release motor assembly LH.
INSPECT SLIDE DOOR LOCK RELEASE MOTOR ASSEMBLY RH
Apply battery voltage to the motor terminals and check the operation of the slide door lock release motor assembly RH.
| OK | ||||||
|---|---|---|---|---|---|---|
|
| Standard Stroke |
|---|
| 26.0 to 30.3 mm (1.02 to 1.19 in.) |
If the result is not as specified, replace the slide door lock release motor assembly RH.