Click here

SLIDE DOOR LOCK RELEASE MOTOR INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT SLIDE DOOR LOCK RELEASE MOTOR ASSEMBLY LH


    1. A01CE0YE02

      Apply battery voltage to the motor terminals and check the operation of the slide door lock release motor assembly LH.

      OK
      Tester Connection Condition Specified Condition
      L7-1 (SD+) - L7-2 (SD-) Battery voltage is applied to terminal 1 (SD+) Lock released
      Standard Stroke
      26.0 to 30.3 mm (1.02 to 1.19 in.)

      • If the result is not as specified, replace the slide door lock release motor assembly LH.

  2. Click here

    INSPECT SLIDE DOOR LOCK RELEASE MOTOR ASSEMBLY RH


    1. A01CDSHE02

      Apply battery voltage to the motor terminals and check the operation of the slide door lock release motor assembly RH.

      OK
      Tester Connection Condition Specified Condition
      K7-1 (SD+) - K7-2 (SD-) Battery voltage is applied to terminal 1 (SD+) Lock released
      Standard Stroke
      26.0 to 30.3 mm (1.02 to 1.19 in.)

      • If the result is not as specified, replace the slide door lock release motor assembly RH.