POWER SLIDE DOOR CONTROL SWITCH (for Roof Side) INSPECTION


  1. INSPECT NO. 2 POWER SLIDE DOOR CONTROL SWITCH (SATELLITE SWITCH)


    1. A01CBS4E04

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      R14-4 (CSW) - R14-7 (E) Pushed (for LH) Below 1 Ω
      R14-4 (CSW) - R14-7 (E) OFF 10 kΩ or higher
      R14-5 (CSW) - R14-7 (E)*1 Pushed (for RH) Below 1 Ω
      R14-5 (CSW) - R14-7 (E)*1 OFF 10 kΩ or higher

      • *1: w/ Power Slide Door RH

    2. Apply battery voltage to the No. 2 power slide door control switch (satellite switch) and check that the switch illuminates.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → R14-1 (ILL+)

      Battery negative (-) → R14-2 (ILL-)

      Illuminates

      If the result is not as specified, replace the bulb.