POWER WINDOW MASTER SWITCH INSPECTION


  1. INSPECT MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY


    1. A01CAP4E01

      Check that the LED illuminates.


      1. Apply battery voltage to the multiplex network master switch assembly and check that the LED illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 18 (LED)

        Battery negative (-) → 12 (GND)

        LED illuminates

        If the result is not as specified, replace the multiplex network master switch assembly.