ECO SWITCH INSPECTION


  1. INSPECT ECO MODE SWITCH (ECO SWITCH ASSEMBLY)


    1. A01CESKE04

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      6 (E) - 9 (ECU) ECO mode switch (eco switch assembly) on Below 1 Ω
      6 (E) - 9 (ECU) ECO mode switch (eco switch assembly) off 10 kΩ or higher

      If the result is not as specified, replace the ECO mode switch (eco switch assembly).

    2. Check that the switch illuminates.


      1. Apply battery voltage to the ECO mode switch (eco switch assembly) and check that the switch illuminates.

        OK
        Tester Connection Specified Condition

        Battery positive (+) → Terminal 8 (ILL+)

        Battery negative (-) → Terminal 7 (ILL-)

        Illuminates

        If the result is not as specified, replace the ECO mode switch (eco switch assembly).