Click here

AMBIENT TEMPERATURE SENSOR INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT AMBIENT TEMPERATURE SENSOR


    1. A01CDWTE07

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
      1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
      1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
      1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
      1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
      1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
      1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
      1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
      1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
      1 - 2 60°C (140°F) 0.36 to 0.50 kΩ
      Table 1. Text in Illustration
      *1

      Component without harness connected

      (Ambient Temperature Sensor)

      *2 Sensing Portion
      Note:
      • Hold the sensor only by its connector. Touching the sensor may change the resistance value.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tip:

      As the temperature increases, the resistance decreases (see the graph).

      If the resistance is not as specified, replace the ambient temperature sensor.