INSPECT ROOM HUMIDITY SENSOR
Disconnect the room humidity sensor connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, repair or replace the wire harness or connector.
Reconnect the room humidity sensor connector.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Do not touch the room humidity sensor because it may be affected by body temperature and may not work properly.
Hold the sensor only by its connector.
The output voltage at the ambient temperature 25°C (77°F) is shown above.
As the humidity increases, the voltage increases (see the graph).
If the voltage is not as specified, replace the room humidity sensor.