DESCRIPTION
The smog ventilation sensor is installed on the front of the condenser to control automatic air inlet. This sensor detects CO and HC in the emission gas and transmits signals to the A/C amplifier.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1418/18 | Open or short in smog ventilation sensor circuit (HC, CO) |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Emission Gas Sensor | Emission gas (HC, CO) / Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | - |
| OK |
|---|
| The display is as specified in the Normal Condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE A/C AMPLIFIER Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - BODY GROUND)
Disconnect the smog ventilation sensor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - BATTERY)
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT SMOG VENTILATION SENSOR
Remove the smog ventilation sensor.
Connect a battery positive (+) lead to terminal 3 (IG) and a negative (-) lead to terminal 6 (E).
Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 2 (DGS).
| OK |
|---|
| When the sensor is exposed to the exhaust gas, the resistance increases. |
Tech Tips
The resistance before blowing exhaust gas is 10 kΩ to 40 kΩ.
| NG |
|
REPLACE SMOG VENTILATION SENSOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - A/C AMPLIFIER)
Disconnect the A/C amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE A/C AMPLIFIER Click here