Click here

OTTOMAN SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT OTTOMAN SWITCH


    1. A01CB9PE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (for RHD)
      Tester Connection Switch Condition Specified Condition
      W5-4 (E2) - W5-3 (R) on (Upward) Below 1 Ω
      W5-2 (B) - W5-5 (H) on (Upward) Below 1 Ω
      W5-1 (E) - W5-5 (H) off Below 1 Ω
      W5-3 (R) - W5-4 (E2) off Below 1 Ω
      W5-1 (E) - W5-5 (H) on (Downward) Below 1 Ω
      W5-2 (B) - W5-3 (R) on (Downward) Below 1 Ω
      Standard Resistance (for LHD)
      Tester Connection Switch Condition Specified Condition
      V10-4 (E2) - V10-3 (H) on (Upward) Below 1 Ω
      V10-2 (B) - V10-5 (R) on (Upward) Below 1 Ω
      V10-1 (E) - V10-5 (R) off Below 1 Ω
      V10-3 (H) - V10-4 (E2) off Below 1 Ω
      V10-1 (E) - V10-5 (R) on (Downward) Below 1 Ω
      V10-2 (B) - V10-3 (H) on (Downward) Below 1 Ω

      If the result is not as specified, replace the ottoman switch.