CEILING LIGHT SWITCH INSPECTION


  1. INSPECT FRONT CEILING LIGHT SWITCH (INTEGRATION CONTROL AND PANEL ASSEMBLY)


    1. A01CGAEE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      2 - 3 Front ceiling light switch not pushed 10 kΩ or higher
      Front ceiling light switch pushed Below 1 Ω

      If the result is not as specified, replace the front ceiling light switch (integration control and panel assembly).

  2. INSPECT REAR CEILING LIGHT SWITCH (INTEGRATION CONTROL AND PANEL ASSEMBLY)


    1. A01CDKDE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      8 (LP+) - 12 (E) Rear ceiling light switch not pushed 10 kΩ or higher
      Rear ceiling light switch pushed Below 1 Ω

      If the result is not as specified, replace the rear ceiling light switch (integration control and panel assembly).