BACK DOOR LOCK INSPECTION


  1. INSPECT BACK DOOR LOCK ASSEMBLY (w/o Back Door Closer System)


    1. A01CD46E09

      Check the operation of the door lock motor.


      1. Move the door lock to the lock position.

      2. Apply the battery voltage to the door lock motor and check the operation of the door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Unlocks

        If the result is not specified, replace the back door lock.

    2. Check the operation of the door courtesy switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 3 Locked 10 kΩ or higher
        1 - 3 Unlocked Below 1 Ω

        If the result is not specified, replace the back door lock.

  2. INSPECT BACK DOOR LOCK ASSEMBLY (w/ Back Door Closer System)


    1. Check the operation of the door lock motor.

      A01CFLPE07

      1. Apply the battery voltage to the door lock motor and check the operation of the door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 1 (DC+)

        Battery negative (-) → Terminal 2 (DC-)

        Latch turns to full-latch position

        Battery positive (+) → Terminal 2 (DC-)

        Battery negative (-) → Terminal 1 (DC+)

        Latch turns to open-latch position

        If the result is not specified, replace the back door lock.

    2. Check the operation of the switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Full-latch Switch
        Tester Connection Door Lock Latch Position Specified Condition
        5 (HAF) - 4 (GND) Over-latch Below 1 Ω
        5 (HAF) - 4 (GND) Open-latch 10 kΩ or higher
        5 (HAF) - 4 (GND) Full-latch 10 kΩ or higher
        5 (HAF) - 4 (GND) Half-latch 10 kΩ or higher
        Sector Switch
        Tester Connection Door Lock Latch Position Specified Condition
        6 (POS) - 4 (GND) Open-latch Below 1 Ω
        6 (POS) - 4 (GND) Over-latch 10 kΩ or higher
        6 (POS) - 4 (GND) Full-latch 10 kΩ or higher
        6 (POS) - 4 (GND) Half-latch 10 kΩ or higher
        Back Door Courtesy Light Switch
        Tester Connection Door Lock Latch Position Specified Condition
        3 (BDCY) - 4 (GND) Open-latch Below 1 Ω
        3 (BDCY) - 4 (GND) Half-latch Below 1 Ω
        3 (BDCY) - 4 (GND) Full-latch 10 kΩ or higher
        3 (BDCY) - 4 (GND) Over-latch 10 kΩ or higher

        If the result is not specified, replace the back door lock.