AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P2714 Click here.

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • TCM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01CB5NE34

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SLT)


    1. A01CE1UE06

      Remove the TCM from the transaxle.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      12 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      12 (SLT+) - Body ground Always 10 kΩ or higher
      7 (SLT-) - Body ground Always 10 kΩ or higher
      12 (SLT+) - All other terminals except 7 (SLT-) Always 10 kΩ or higher
      7 (SLT-) - All other terminals except 12 (SLT+) Always 10 kΩ or higher
      Result
      Result Proceed to
      OK B
      NG A

    B
    A
  2. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01CGF5E08

      Remove shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.

    NG
    OK