GENERATOR (for 80A Type) REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note


    • After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

    • When disconnecting the cable, some systems need too be initialized after the cable is reconnected Click here.

  2. REMOVE AIR CLEANER AND HOSE


    1. A00XFTV

      Detach the 3 clamps and disconnect the mass air flow meter connector.

    2. A00XHYV

      Detach the 4 clamps.

    3. Loosen the hose clamp and remove the air cleaner and hose.

  3. REMOVE FAN AND GENERATOR V BELT


    1. A00XEZ2E01

      Use the hexagonal part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the V belt. Then remove the V belt.

      Note

      When removing the V belt, do not use the bolt of the idle pulley.

      Tech Tips

      After removing the drive belt, move the tensioner upward to the maximum amount.

  4. REMOVE GENERATOR ASSEMBLY


    1. A00O8UY

      Remove the terminal cap.

    2. Remove the nut and generator wire.

    3. Disconnect the generator connector.

    4. A00O3P0

      Remove the 2 bolts and generator.