ULTRASONIC SENSOR (for Front) INSPECTION


  1. INSPECT NO. 1 ULTRASONIC SENSOR

    A009AUDE01
    Text in Illustration
    *a

    Component without harness connected

    (No. 1 Ultrasonic Sensor)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (BI) - 5 (EI) Always 10 kΩ or higher
      1 (BI) - 2 (BO) Always 10 kΩ or higher
      3 (SI) - 4 (SO) Always Below 1 Ω
      5 (EI) - 6 (EO) Always Below 1 Ω

      If the result is not as specified, replace the No. 1 ultrasonic sensor.