INSPECTION PROCEDURE
PROCEDURE
CHECK CELLULAR PHONE
Check if the other caller can hear your voice properly.
| OK |
|---|
| Your voice can be heard correctly. |
| NG |
|
CELLULAR PHONE IS FAULTY |
| OK |
|
CHECK SETTINGS
Check if the mute switch is set to on.
| OK |
|---|
| Mute switch is not set to on. |
| NG |
|
TURN MUTE SWITCH OFF |
| OK |
|
CHECK SETTINGS (OPERATION CHECK)
Enter the "Hand-free Volume Setting" screen. Refer to "Check Hands-free Volume Setting" in Operation Check Click here.
Adjust "Send Voice Level" and check that the other caller an hear your voice.
Tech Tips
Adjusting "Send Voice Level" may deteriorate the sound quality.
The "Send Voice Level" can be set to 10 different levels, -5 to +4.
| OK |
|---|
| Malfunction disappears. |
| NG |
|
CHECK MICROPHONE (NAVIGATION CHECK MODE) Click here |
| OK |
|
END
CHECK MICROPHONE (NAVIGATION CHECK MODE)
| *a | Microphone Input Level Meter |
| *b | Recording Switch |
| *c | Stop Switch |
| *d | Play Switch |
| *e | Recording Indicator |
Enter "Microphone & Voice Recognition Check" (Check Mic & Voice Recognition) Click here.
When voice is input into the microphone, check that the microphone input level meter changes according to the input voice.
Push the recording switch and perform voice recording.
Tech Tips
Select the recording switch with the blower motor of the air conditioning system stopped. If an outlet of the air conditioning system is facing the microphone, noise may be recorded.
Voice can be recorded for up to 5 seconds.
Check that the recording indicator remains on while recording and that the recorded voice is played normally without noise or distortion.
| OK |
|---|
| All check results are normal. |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| OK |
|
REPLACE DISPLAY AND NAVIGATION MODULE DISPLAY Click here