INSPECTION PROCEDURE
PROCEDURE
CHECK HARD DISK DRIVE (OPERATION CHECK)
| *a | Result |
Enter the "Failure Diagnosis" screen Click here.
Select "HDD Check" and check the result.
| OK |
|---|
| "OK" is displayed. |
Tech Tips
After "HDD Check" is selected, it may take a while until the result is displayed.
| NG |
|
REPLACE DISPLAY AND NAVIGATION MODULE DISPLAY Click here |
| OK |
|
CHECK CABIN
Check that condensation is not likely to occur in the cabin, and that the temperature is not high or extremely low in the cabin.
Tech Tips
A humid cabin and a rapid change in temperature may lead to condensation. Condensation in the cabin may cause a short circuit.
The navigation system may not operate normally when the temperature is -20°C (-4°F) or less, or 65°C (149°F) or higher.
| OK |
|---|
| Condensation is not likely being produced and the temperature is not high or extremely low. |
| NG |
|
SET CABIN TO APPROPRIATE TEMPERATURE |
| OK |
|
SET DESTINATION
Set another destination and check if the system can calculate the route correctly.
| OK |
|---|
| Route can be correctly calculated. |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| OK |
|
NORMAL OPERATION