VACUUM PUMP (for 1KD-FTV) INSPECTION


  1. CHECK OPERATION OF CHECK VALVE SUB-ASSEMBLY

    A0098XJE03
    Text in Illustration
    *a Hose Side
    *b Vacuum Pump Side
    A009BSG Air

    1. Check that air flows from the hose side to the pump side.

    2. Check that air does not flow from the pump side to the hose side.

      If necessary, replace the check valve sub-assembly.

  2. CHECK VACUUM PUMP HOUSING

    A009BTU

    1. Check the inside surface of the housing for scoring.

      If necessary, replace the vacuum pump assembly.