CONTROL VALVE ASSEMBLY INSPECTION


  1. INSPECT NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY


    1. A009BDIE03
      Text in Illustration
      *a

      Component without harness connected

      (No. 2 Height Control Valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (LH+) - 2 (E) 15 to 25°C (59 to 77°F) 10 to 14 Ω
      3 (RH+) - 2 (E)
    2. Check the operating sound of the height control valve when battery voltage is applied to the terminals.

      OK
      Measurement Condition Specified Condition
      1 (LH+) - 2 (E) Sound of No. 2 height control valve operating can be heard
      3 (RH+) - 2 (E)

      If the result is not as specified, replace the No. 2 height control valve sub-assembly.