PARK / NEUTRAL POSITION SWITCH INSPECTION


  1. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

    A0095A9E10
    Text in Illustration
    *a

    Component without harness connected

    (Park/Neutral Position Switch)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition

      • 2 (RB) - 6 (PL)

      • 4 (B) - 5 (L)

      Shift lever in P Below 1 Ω
      2 (RB) - 1 (RL) Shift lever in R Below 1 Ω

      • 2 (RB) - 9 (NL)

      • 4 (B) - 5 (L)

      Shift lever in N Below 1 Ω
      2 (RB) - 7 (DL)
      • Shift lever in D

      • Shift lever in S, "+" or "-"

      Below 1 Ω

      • 2 (RB) - 6 (PL)

      • 4 (B) - 5 (L)

      Shift lever not in P 10 kΩ or higher
      2 (RB) - 1 (RL) Shift lever not in R 10 kΩ or higher

      • 2 (RB) - 9 (NL)

      • 4 (B) - 5 (L)

      Shift lever not in N 10 kΩ or higher
      2 (RB) - 7 (DL)
      • Shift lever not in D

      • Shift lever not in S, "+" or "-"

      10 kΩ or higher

      If the result is not as specified, replace the switch.