DESCRIPTION
If the manual up/down function does not operate, there may be a malfunction in the power window regulator switch, front power window regulator motor, harness or connector.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Tech Tips
Since the power window control system has functions that use LIN communication, first confirm that there is no malfunction in the communication system by inspecting the LIN communication functions in accordance with the "How to Proceed with Troubleshooting" procedures. Then, conduct the following inspection procedure.
PROCEDURE
CHECK FOR DTC (B2312)
Check if DTC B2312 is output Click here.
| OK |
|---|
| DTC B2312 is not output. |
| NG |
|
GO TO DTC B2312 Click here |
| OK |
|
READ VALUE USING INTELLIGENT TESTER (POWER WINDOW REGULATOR SWITCH)
Use the Data List to check if the front power window regulator motor is functioning properly Click here.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| P Door P/W Up SW | Front passenger side power window manual up signal / ON or OFF | ON: Front passenger side power window manual up switch operated OFF: Front passenger side power window regulator switch not operated |
- |
| P Door P/W Down SW | Front passenger side power window manual down signal / ON or OFF | ON: Front passenger side power window manual down switch operated OFF: Front passenger side power window regulator switch not operated |
- |
| OK |
|---|
| On tester screen, each item changes between ON and OFF according to above chart. |
| NG |
|
INSPECT POWER WINDOW REGULATOR SWITCH ASSEMBLY Click here |
| OK |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (POWER WINDOW)
Select the Active Test, use the intelligent tester to generate a control command, and then check that power window regulator motor operates Click here.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Power Window | Passenger side power window | OFF/UP/DOWN | - |
| OK |
|---|
| The power window regulator motor operates normally. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
| B |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH Click here |
| C |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH Click here |
| A |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here
INSPECT POWER WINDOW REGULATOR SWITCH ASSEMBLY
Remove the power window regulator switch Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE POWER WINDOW REGULATOR SWITCH ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR SWITCH ASSEMBLY - BODY GROUND)
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Power Window Regulator Switch Assembly) |
Disconnect the J1*1 or K10*2 power window regulator switch connector.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY)
*1: for LHD
*2: for RHD
Disconnect the J1*1 or K10*2 power window regulator switch connector.
Disconnect the J7*1 or K7*2 power window regulator motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY - BATTERY AND BODY GROUND)
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Front Power Window Regulator Motor Assembly) |
Disconnect the J7*1 or K7*2 power window regulator motor connector.
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
| B |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH Click here |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH Click here