INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
Temporarily install the sensor to the exhaust pipe by hand.
| *a | Fulcrum Length |
Using SST, tighten the sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). When using a torque wrench with a fulcrum length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
Connect the sensor connector.
INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
Temporarily install the sensor to the exhaust pipe by hand.
| *a | Fulcrum Length |
Using SST, tighten the sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). When using a torque wrench with a fulcrum length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.