SUSPENSION CONTROL SERVICE DATA

Suspension Control System
Height difference of left and right sides 20 mm (0.787 in.) or less
Fluid temperature is 20°C (68°F)

2.6 to 3 MPa (26.6 to 30.5 kgf/cm2, 377 to 435 psi)

Height Control Compressor
Tester Connection Condition Specified Condition
2 (L) - 1 (B) 15 to 25°C (59 to 77°F) 10 to 14 Ω
Control Valve Assembly
Tester Connection Condition Specified Condition
1 (LH+) - 2 (E) 15 to 25°C (59 to 77°F) 10 to 14 Ω
3 (RH+) - 2 (E)
Height Control Sensor
Tester Connection Condition Specified Condition

3 (SHG) - 2 (SHRR)

3 (SHG) - 2 (SHRL)

High (45°) 4.4 to 4.6 V
Normal (0°) 2.3 to 2.6 V
Low (-45°) 0.4 to 0.6 V
Front Acceleration Sensor
Tester Connection Condition Specified Condition
1 (SGFR) - 2 (SGR) Sensor stationary Approx. 2.0 to 2.5 V
Sensor tilted Changes between approx. 0.9 and 2.3 V
Rear Acceleration Sensor
Tester Connection Condition Specified Condition
1 (SGRR) - 2 (SGND) Sensor stationary Approx. 2.0 to 2.5 V
Sensor tilted Changes between approx. 0.9 and 2.3 V
Absorber Control Actuator
Tester Connection Condition Specified Condition
1 (FAL+) - 2 (FAL-) Always 6.4 to 7.2 V
3 (FBL+) - 4 (FBL-)
1 (FAR+) - 2 (FAR-)
3 (FBR+) - 4 (FBR-)