1KD-FTV INTAKE / EXHAUST SERVICE DATA

Turbocharger boost pressure Standard pressure

5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)

Intake manifold Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
Turbocharger Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00441 in.)
Exhaust pipe Compression spring Minimum free length 43 mm (1.693 in.)