RELAY ON-VEHICLE INSPECTION


  1. INSPECT STARTER RELAY (ST)


    1. A00O3XJE64

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.

  2. INSPECT GLOW RELAY


    1. A00O3XJE63

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the glow relay.