VACUUM SWITCHING VALVE (w/o DPF) ON-VEHICLE INSPECTION


  1. INSPECT VACUUM SWITCHING VALVE (for EGR Cut)


    1. A0097JIE05
      Text in Illustration
      *a

      Component without harness connected

      (Vacuum Switching Valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 37 to 44 Ω

      1 - Body ground

      2 - Body ground

      20°C (68°F) 1 MΩ or higher

      If the result is not as specified, replace the vacuum switching valve.

    2. Check operation of the vacuum switching valve.


      1. A0096CWE03
        Text in Illustration
        *1 Port E
        *2 Filter

        Attach a vacuum pump to port E and check that vacuum does not flow from the filter to port E.

      2. A0096LYE03
        Text in Illustration
        *1 Port E
        *2 Filter

        Apply battery voltage across terminals 1 and 2.

      3. Attach a vacuum pump to port E and check that vacuum flows from the filter to port E.

        If the result is not as specified, replace the vacuum switching valve.

  2. INSPECT VACUUM SWITCHING VALVE (for EGR Bypass Valve)


    1. A009C0NE01
      Text in Illustration
      *a

      Component without harness connected

      (Vacuum Switching Valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 37 to 44 Ω

      1 - Body ground

      2 - Body ground

      20°C (68°F) 1 MΩ or higher

      If the result is not as specified, replace the vacuum switching valve.

    2. A0098JJE01
      Text in Illustration
      *1 Port E
      *2 Port F
      *3 Vacuum
      *4 Air
      *5 Filter

      Check operation of the vacuum switching valve.


      1. When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.

      2. A0094F7E01
        Text in Illustration
        *1 Port E
        *2 Port F
        *3 Air

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the vacuum switching valve.