HAZARD WARNING SWITCH INSPECTION

  1. INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH)

    1. Measure the resistance according to the value(s) in the table below.

      A011T3BE10
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (HAZ) - 6 (GND) Hazard switch off 10 kΩ or higher
      Hazard switch on Below 1 Ω
      Text in Illustration
      *a

      Component without harness connected

      (Air Conditioning Control Assembly (Hazard Switch))

      If the result is not as specified, replace the air conditioning control assembly.