DESCRIPTION
The jam protection function operates within a specified range during the manual up or auto up operation.
INSPECTION PROCEDURE
Note
If a power window regulator motor assembly has been replaced with a new one, initialize the power window control system Click here.
PROCEDURE
PERFORM INITIALIZATION (DRIVER DOOR WINDOW MOTOR)
Initialize the power window regulator motor assembly LH (for driver door) Click here.
| NEXT |
|
CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION (FOR DRIVER DOOR))
Check if the power window auto up and down function operate normally Click here.
| OK |
|---|
| Driver door auto up and down function is normal. |
| NG |
|
GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table) Click here |
| OK |
|
CHECK JAM PROTECTION FUNCTION OPERATING RANGE
Check if the jam protection function operates normally for the driver door power window.
Tech Tips
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
| OK |
|---|
| Jam protection function operates normally. |
| NG |
|
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (FOR DRIVER DOOR) Click here |
| OK |
|
END (PROBLEM DUE TO INITIALIZATION FAILURE)