OCCUPANT CLASSIFICATION SYSTEM DATA LIST / ACTIVE TEST

  1. DATA LIST

    Tech Tips

    Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    1. Turn the ignition switch off.

    2. Connect the Techstream to the DLC3.

    3. Turn the ignition switch to ON.

    4. Turn the Techstream on.

    5. Enter the following menus: Body Electrical / Occupant Detection / Data List.

    6. Check the values by referring to the table below.

      Occupant Detection
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      IG Switch

      Ignition switch condition/

      ON: Ignition switch ON

      OFF: Ignition switch off

      ON/OFF -
      Passenger Buckle SW

      Passenger side buckle switch/

      Set: The seat belt is fastened

      Unset: The seat belt is not fastened

      NG: Data is not determined

      Set/Unset -
      Passenger Classification

      Passenger classification/

      AM50: Adult is seated

      AF05: Adult is seated

      Child: Child is seated

      CRS: Child restraint system is installed

      OFF: Vacant

      AM50/AF05/Child/CRS/OFF -
      Sensor Range Info

      Sensor range information/

      OK: The value of a sensor is within the range

      NG: The value of a sensor is over the range

      OK -
      RL Sensor Range Info

      Rear left sensor range information/

      OK: Sensor range is -10.00 to 30.00 kg (-22.05 to 66.13 lb)

      Min.: Less than -10.00 kg (-22.05 lb)

      Max.: 30.00 kg (66.13 lb)

      OK -
      RR Sensor Range Info

      Rear right sensor range information/

      OK: Sensor range is -10.00 to 30.00 kg (-22.05 to 66.13 lb)

      Min.: Less than -10.00 kg (-22.05 lb)

      Max.: More than 30.00 kg (66.13 lb)

      OK -
      RL Sensor Voltage

      Rear left sensor voltage/

      Min.: 0.000 V

      Max.: 19.800 V

      0.000 to 5.000 V -
      RR Sensor Voltage

      Rear right sensor voltage/

      Min.: 0.000 V

      Max.: 19.800 V

      0.000 to 5.000 V -
      RL Sensor Weight Info

      Rear left sensor weight information/

      Min.: -10.00 kg (-22.05 lb)

      Max.: 30.00 kg (66.13 lb)

      -10.00 to 30.00 kg

      (-22.05 to 66.13 lb)

      -
      RR Sensor Weight Info

      Rear right sensor weight information/

      Min.: -10.00 kg (-22.05 lb)

      Max.: 30.00 kg (66.13 lb)

      -10.00 to 30.00 kg

      (-22.05 to 66.13 lb)

      -
      Total Weight Information

      Total weight information/

      Min.: -40.00 kg (-88.19 lb)

      Max.: 100.00 kg (220.46 lb)

      -40.00 to 100.00 kg

      (-88.19 to 220.46 lb)

      -
      Number of Present DTC

      Number of present DTC recorded/

      Min.: 0, Max.: 255

      0 -
      Number of Past DTC

      Number of past DTC recorded/

      Min.: 0, Max.: 255

      0 -