METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

A011UZ6E34

INSPECTION PROCEDURE

Note

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

PROCEDURE

  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)

    1. Disconnect the I18 combination meter assembly connector.

      A011SNGE03
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I18-7 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      I18-13 (IG+) - Body ground Ignition switch off Below 1 V
      Ignition switch to ON 11 to 14 V
      I18-1 (B) - Body ground Always 11 to 14 V
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

    NG
    OK