VANITY LIGHT SWITCH INSPECTION

  1. INSPECT VISOR ASSEMBLY LH

    1. Inspect the vanity light switch.

      1. Measure the resistance according to the value(s) in the table below.

        A011TNBE01
        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 Visor up 10 kΩ or higher
        1 - 2 Mirror cover fully closed with visor down 10 kΩ or higher
        1 - 2 Mirror cover fully open with visor down Below 1 Ω
        Text in Illustration
        *a

        Component without harness connected

        (Visor Assembly LH)

        *b Visor up
        *c Visor down
        *1 Mirror Cover

        If the result is not as specified, replace the visor assembly LH.

  2. INSPECT VISOR ASSEMBLY RH

    1. Inspect the vanity light switch.

      1. Measure the resistance according to the value(s) in the table below.

        A011U8DE01
        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 Visor up 10 kΩ or higher
        1 - 2 Mirror cover fully closed with visor down 10 kΩ or higher
        1 - 2 Mirror cover fully open with visor down Below 1 Ω
        Text in Illustration
        *a

        Component without harness connected

        (Visor Assembly RH)

        *b Visor up
        *c Visor down
        *1 Mirror Cover

        If the result is not as specified, replace the visor assembly RH.