AUDIO AND VISUAL SYSTEM (for Radio and Display Type without Intuitive Parking Assist System) AVC-LAN Circuit

DESCRIPTION

Each unit of the audio and visual system connected to the AVC-LAN (communication bus) transfers the switch signals using the AVC-LAN.

If a short to +B or short to ground occurs in the AVC-LAN, the audio and visual system will not function normally because communication is not possible.

WIRING DIAGRAM

A011TRJE16

INSPECTION PROCEDURE

Note

After replacing the radio and display receiver assembly of vehicles subscribed to pay-type satellite radio broadcasts, XM radio ID registration is necessary (w/ SDARS System).

Tech Tips

The radio and display receiver assembly is the master unit.

PROCEDURE

  1. INSPECT RADIO AND DISPLAY RECEIVER ASSEMBLY

    1. Disconnect the radio and display receiver assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      A011RKIE02
      Standard Resistance
      Tester Connection Condition Specified Condition
      I134-5 (TX2+) - I134-15 (TX2-) Always 60 to 80 Ω
      Text in Illustration
      *a

      Component without harness connected

      (Radio and Display Receiver Assembly)

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (AVC-LAN CIRCUIT)

    1. Disconnect the radio and display receiver assembly connector.

    2. Disconnect the stereo component amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I69-8 (TX+) - I134-5 (TX2+) Always Below 1 Ω
      I69-7 (TX-) - I134-15 (TX2-) Always Below 1 Ω
      I69-8 (TX+) - Body ground Always 10 kΩ or higher
      I69-7 (TX-) - Body ground Always 10 kΩ or higher
    NG
    OK
  3. INSPECT MALFUNCTIONING PARTS

    1. Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.

      Tech Tips

      • Check all slave units.

      • If disconnecting a slave unit causes the master unit to return to normal operation, the slave unit is defective and should be replaced.

      OK
      Master unit returns to normal operation.
    NG
    OK