INSPECT SHIFT SOLENOID VALVE SL
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Shift Solenoid Valve SL) |
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve SL.
Connect a battery positive (+) lead to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating sound.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| Valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve SL.
INSPECT SHIFT SOLENOID VALVE SLT
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve SLT.
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| Valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve SLT.
INSPECT SHIFT SOLENOID VALVE SLU
Tech Tips
Refer to Inspect Shift Solenoid Valve SLT.
INSPECT SHIFT SOLENOID VALVE SL1
Tech Tips
Refer to Inspect Shift Solenoid Valve SLT.
INSPECT SHIFT SOLENOID VALVE SL2
Tech Tips
Refer to Inspect Shift Solenoid Valve SLT.
INSPECT SHIFT SOLENOID VALVE SL3
Tech Tips
Refer to Inspect Shift Solenoid Valve SLT.
INSPECT SHIFT SOLENOID VALVE SL4
Tech Tips
Refer to Inspect Shift Solenoid Valve SLT.