AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to the system description for DTC P2714 Click here.

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • TCM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

MONITOR STRATEGY

Related DTCs P2716: Shift solenoid valve SLT/Range check
Required sensors/Components Shift solenoid valve SLT
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None

TYPICAL ENABLING CONDITIONS

ALL:
The monitor will run whenever this DTC is not present None
Solenoid current cut status Not cut
Engine switch on (IG)
Starter OFF
Malfunction (A):
Battery voltage 12 V or more
Target current 1 A
Malfunction (B):
Battery voltage 10 V or more and less than 12 V
Target current 0.75 A
Malfunction (C):
Battery voltage 8 V or more
Target current 1 A
Malfunction (D):
Battery voltage 11 V or more
Target current 1 A or more
Malfunction (E):
Battery voltage 11 V or more
Target current 0.1 A or more
Commanded voltage - Last commanded voltage Less than 0.000019 V

TYPICAL MALFUNCTION THRESHOLDS

Malfunction (A) and (B):
Output duty cycle 100% or more
Malfunction (C):
Output duty cycle 0% or less
Malfunction (D):
Output signal monitor No signal
Malfunction (E):
Commanded voltage - Average of monitor voltage 0.035 V or more

COMPONENT OPERATING RANGE

Output duty cycle Less than 100%

WIRING DIAGRAM

A011TKZE34

INSPECTION PROCEDURE

Note

Perform the universal trip to clear permanent DTCs Click here.

PROCEDURE

  1. INSPECT TRANSMISSION WIRE (SLT)

    1. Remove the TCM from the transaxle.

      A011V2EE58
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      12 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      12 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

    NG
    OK
  2. INSPECT SHIFT SOLENOID VALVE SLT

    1. Remove shift solenoid valve SLT.

      A011TNCE01
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
      Text in Illustration
      *1 Shift Solenoid Valve SLT
    3. Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.
    NG
    OK