INSPECT CHARCOAL CANISTER ASSEMBLY
Visually check the charcoal canister assembly.
Visually check the charcoal canister assembly for cracks or damage.
If cracks or damage are found, replace the charcoal canister assembly.
Check canister operation.
With the purge port closed, blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into the vent line port, and check that air flows from the air line port.
| *a | Vent Line Port |
| *b | Air Line Port |
| *c | Purge Line Port |
| *d | Air |
If the result is not as specified, replace the charcoal canister assembly.
With the vent port closed, blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into the air line port, and check that air flows from the purge line port.
| *a | Vent Line Port |
| *b | Air Line Port |
| *c | Purge Line Port |
| *d | Air |
If the result is not as specified, replace the charcoal canister assembly.
Check for air leaks.
Connect a pressure gauge to the vent line port of the charcoal canister assembly.
| *1 | Pressure Gauge |
| *a | Vent Line Port |
| *b | Air Line Port |
| *c | Purge Line Port |
With the purge line port and the air line port closed, apply 20 kPa (150 mmHg, 5.91 in.Hg) of pressurized air into the vent line port, then confirm that pressure is retained for 1 minute.
If the result is not as specified, replace the charcoal canister assembly.
Check the charcoal canister leak detection pump sub-assembly.
Connect a positive (+) lead from the battery to terminal 5 and a negative (-) lead to terminal 1.
Check that a clicking sound is heard from the charcoal canister leak detection pump sub-assembly.
If the result is not as specified, replace the charcoal canister leak detection pump sub-assembly.