| DTC Code | DTC Name |
|---|---|
| P2759 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) |
DESCRIPTION
Refer to the system description for DTC P2757 Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.
MONITOR STRATEGY
| Related DTCs | P2759: Shift solenoid valve SLU/Range check |
| Required sensors/Components | Shift solenoid valve SLU |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Battery voltage | 12 V or more |
| Battery voltage | 10 V or more and less than 12 V |
| CPU commanded duty | Less than 75% |
TYPICAL MALFUNCTION THRESHOLDS
| Output duty cycle | 100% or more |
COMPONENT OPERATING RANGE
| Output duty cycle | More than 3% and less than 100% |
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Perform the universal trip to clear permanent DTCs Click here.
PROCEDURE
CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLU CIRCUIT)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to ECM) |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR) Click here |
| A |
|
REPLACE ECM Click here
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
Disconnect the harness connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT TRANSMISSION WIRE (SLU)
Remove the wiring harness connector from the automatic transaxle.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Transmission Wire) |
| NG |
|
INSPECT SHIFT SOLENOID VALVE SLU Click here |
| OK |
|
REPLACE WIRING HARNESS CONNECTOR Click here
INSPECT SHIFT SOLENOID VALVE SLU
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
| OK |
|---|
| Valve moves and makes an operating sound. |
| *1 | Shift Solenoid Valve SLU |
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLU Click here |
| OK |
|
REPLACE TRANSMISSION WIRE Click here