VALVE BODY ASSEMBLY INSPECTION

  1. INSPECT SHIFT SOLENOID VALVE SL

    1. Measure the resistance according to the value(s) in the table below.

      A011T5LE04
      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector (SL) - Solenoid Body (SL) 20°C (68°F) 11 to 15 Ω
      Text in Illustration
      *a Shift Solenoid Valve SL

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect a positive (+) lead from the battery to the terminal of the solenoid connector, and a negative (-) lead to the solenoid body, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The valve moves and makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE (SLT, SLU, SL1, SL2, SL3, SL4)

    1. Measure the resistance according to the value(s) in the table below.

      A011TRQE26
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT, SLU, SL1, SL2, SL3, SL4)

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The valve moves and makes an operating sound.

      If the operation cannot be done as specified, replace the shift solenoid valve.