INSTALL AIR FUEL RATIO SENSOR (for Bank 2 Sensor 1)
Temporarily install the sensor to the exhaust pipe by hand.
| *1 | Fulcrum Length |
Using SST, tighten the sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
Temporarily install the sensor to the exhaust pipe by hand.
| *1 | Fulcrum Length |
Using SST, tighten the sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY